Abstract 


Objectives

To assess the prognostic value of determining anti-endotoxin core antibodies (EndoCab) immunoglobulin (Ig)G and IgM in medical patients with sepsis syndrome in order to identify patient subgroups that may profit from endotoxin-neutralizing therapy. The findings were correlated with clinical outcome, endotoxin levels and sepsis score.

Design

Cohort study with a follow-up period of 30 days.

Setting

Medical intensive care units (2) of a university hospital.

Patients and methods

Twenty-nine patients who fulfilled the criteria of sepsis syndrome and did not present with septic shock or had not been treated with antibiotics for more than 3 days were included in the study. Twenty-one intensive care patients without infections served as controls for antibody concentrations.

Interventions

Blood samples were obtained from indwelling arterial catheters or direct venipuncture on admission and daily thereafter until transfer to a regular unit. Sepsis scores were determined daily.

Results

The mortality rate at 30 days was 44.8% (13 out of 29). Sepsis patients had significantly lower initial EndoCab IgM and IgG concentrations than controls. Initial EndoCab IgG concentrations were significantly lower in non-survivors of sepsis syndrome but not in survivors compared to controls (median concentrations 51.5 vs 110.1 vs 245.4 MU/ml). EndoCab IgM and IgG were lower in non-survivors compared to survivors, though that difference failed to reach significance (p = 0.11 in both cases). Depletion of initial EndoCab IgM concentrations (defined as a value below the 10th percentile of a control population) was present in 15 patients, 9 of whom died, and depletion of IgG in five patients, four of whom died. EndoCab IgM and IgG concentrations rose concordantly in survivors and non-survivors in the course of the disease. Endotoxin levels were significantly higher in non-survivors compared to controls but not in survivors. A sepsis score of 21 and higher was associated with 90.9% mortality (specificity 93.8%, sensitivity 76.9%).

Conclusions

Decreased EndoCab IgG concentrations are associated with increased mortality in medical patients with sepsis syndrome. The measurement of initial anti-endotoxin antibodies may provide a useful tool to identify septic patients who profit potentially from endotoxin neutralizing therapy, however considerable overlap of antibody concentrations warrants additional parameters. The sepsis score is easy to determine and useful in the evaluation of medical patients with sepsis.

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/170639521
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/170639521

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1007/s001340050877

Supporting
Mentioning
Contrasting
1
26
0

Article citations


Go to all (29) article citations