Europe PMC

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


Purpose

This study tested the validity of four motion sensors for measuring energy expenditure (EE) during moderate intensity physical activities in field and laboratory settings. We also evaluated the accuracy of the EE values for selected moderate activities listed in the 1993 Compendium of Physical Activities.

Methods

A total of 81 participants (age 19-74 yr) completed selected tasks from six general categories: yardwork, housework, occupation, family care, conditioning, and recreation. Twelve individuals performed each of the 28 activities examined. During each activity, EE was measured using a portable metabolic measurement system. Participants also wore three accelerometers (Computer Science and Applications [CSA], Inc. model 7164; Caltrac; and Kenz Select 2) and the Yamax SW-701 electronic pedometer. For the CSA device, three previously developed regression equations were used to convert accelerometer scores to EE.

Results

The mean error scores (indirect calorimetry minus device) across all activities were: CSA1, 0.97 MET; CSA2, 0.47 MET, CSA3, 0.05 MET; Caltrac, 0.83 MET; Kenz, 0.96 MET; and Yamax, 1.12 MET. The correlation coefficients between indirect calorimetry and motion sensors ranged from r = 0.33 to r = 0.62. The energy cost for power mowing and sweeping/mopping was higher than that listed in the 1993 Compendium (P < 0.05), and the cost for several household and recreational activities was lower (P < 0.05).

Conclusion

Motion sensors tended to overpredict EE during walking. However, they underpredicted the energy cost of many other activities because of an inability to detect arm movements and external work. These findings illustrate some of the limitations of using motion sensors to predict EE in field settings.

References 


Articles referenced by this article (33)


Show 10 more references (10 of 33)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/170639238
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/170639238

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1097/00005768-200009001-00006

Supporting
Mentioning
Contrasting
17
291
3

Article citations


Go to all (261) article citations