Abstract
References
Articles referenced by this article (10)
Phonoangiography: a new noninvasive diagnostic method for studying arterial disease.
Proc Natl Acad Sci U S A, (2):935-942 1970
MED: 5289030
Title not supplied
Proc San Diego Biomed Symp 1973
The technique of estimating the instantaneous aortic blood velocity in man from the pressure gradient.
Am Heart J, 359-366 1961
MED: 13687129
Pseudo-sound generation at atherosclerotic constrictions in arteries.
Bull Math Biol, (2):143-155 1974
MED: 4418937
Title not supplied
Circulation, (2) 1971
The place of ophthalmodynamometry in the investigation of cerebrovascular disease.
Brain, 274-288 1961
MED: 13762824
Ophthalmosonometry. An ultrasonic method for assessing carotid blood flow.
J Neurosurg, (3):238-246 1969
MED: 4976394
Direct thermometry, ophthalmodynamometry, auscultation and palpation in extracranial cerebrovascular disease: an evaluation of rapid diagnostic methods.
Stroke, (4):205-218 1970
MED: 5522918
Opacity pulse propagation measurements in humans: atraumatic screening for carotid arterial occlusion.
Stroke, (6):411-418 1970
MED: 5523001
Noninvasive detection and evaluation of carotid occlusive disease.
Arch Surg, (4):528-535 1973
MED: 4696726
Citations & impact
Impact metrics
Article citations
A 3D scaling law for supravalvular aortic stenosis suited for stethoscopic auscultations.
Heliyon, 10(4):e26190, 15 Feb 2024
Cited by: 0 articles | PMID: 38390109 | PMCID: PMC10881376
Ophthalmic artery reversal predicts contralateral body weakness symptoms better than carotid Doppler velocity-preliminary results.
Ann Transl Med, 11(12):408, 27 Nov 2023
Cited by: 1 article | PMID: 38213804 | PMCID: PMC10777211
A CFD-FFT approach to hemoacoustics that enables degree of stenosis prediction from stethoscopic signals.
Heliyon, 9(7):e17643, 29 Jun 2023
Cited by: 1 article | PMID: 37449099 | PMCID: PMC10336451
Vascular Auscultation of Carotid Artery: Towards Biometric Identification and Verification of Individuals.
Sensors (Basel), 21(19):6656, 07 Oct 2021
Cited by: 0 articles | PMID: 34640975 | PMCID: PMC8512563
Auscultation System for Acquisition of Vascular Sounds - Towards Sound-Based Monitoring of the Carotid Artery.
Med Devices (Auckl), 13:349-364, 30 Oct 2020
Cited by: 1 article | PMID: 33162758 | PMCID: PMC7642592
Go to all (86) article citations
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Correlation of spectral phonoangiography and carotid angiography with gross pathology in carotid stenosis.
N Engl J Med, 305(8):417-419, 01 Aug 1981
Cited by: 25 articles | PMID: 7254278
Quantitative carotid phonoangiography.
Stroke, 12(6):798-803, 01 Nov 1981
Cited by: 14 articles | PMID: 7303070
Diagnosis of carotid stenosis by bruit spectral analysis.
Am J Surg, 144(2):207-210, 01 Aug 1982
Cited by: 3 articles | PMID: 7102927
Carotid sonography.
Radiology, 178(2):303-313, 01 Feb 1991
Cited by: 33 articles | PMID: 1987583
Review