Abstract 


Purpose

To characterize the pupil light reflex (PLR), electroretinographic (ERG) and tonometric parameters which might be of importance for the in vivo characterization of mouse models of chronic ocular hypertension.

Methods

C57/BL6 mice were used for experiments. The PLR was evaluated with a computerized pupillometer (n = 14), ERGs were recorded simultaneously from both eyes (n = 23) and IOP was measured with a modified Goldmann tonometer (n = 23).

Results

The analysis of the PLR parameters confirmed the consensual PLR did not have significantly different amplitude (p > 0.1) and latency time (p > 0.1) compared to the direct PLR. However, PLR velocity (p = 0.004) was significantly smaller in the consensual PLR. Electroretinography revealed a-wave amplitude of 168.3 +/- 9.6 microV with latency of 27.5 +/- 0.6 ms and b-wave 403 +/- 28.8 microV with latency of 22.7 +/- 0.6 ms. The flicker ERG recording revealed amplitudes of 20.6 +/- 2.4 microV. Tonometry experiments revealed that modified Goldmann tonometer measurements correlated well with invasive manometry (r(2) = 0.89). The mean IOP of the mouse was 15.3 +/- 0.6 mmHg.

Conclusions

Consensual PLR in mice is relatively slower than the direct PLR, but retains the same degree of constriction comparing to the direct PLR. A modified Goldmann tonometer seems to be a reliable non-invasive tool for IOP measurements in mice.

References 


Articles referenced by this article (24)


Show 10 more references (10 of 24)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/136582903
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/136582903

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1076/ceyr.26.5.371.15439

Supporting
Mentioning
Contrasting
5
26
0

Article citations


Go to all (18) article citations