Europe PMC

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


In retrospective radiation treatment (RT) dosimetry, a surrogate anatomy is often used for patients without 3D CT. To gain insight in what the crucial aspects in a surrogate anatomy are to enable accurate dose reconstruction, we investigated the relation of patient characteristics and internal anatomical features with deviations in reconstructed organ dose using surrogate patient's CT scans. Abdominal CT scans of 35 childhood cancer patients (age: 2.1-5.6 yr; 17 boys, 18 girls) undergoing RT during 2004-2016 were included. Based on whether an intact right or left kidney is present in the CT scan, two groups were formed each containing 24 patients. From each group, four CTs associated with Wilms' tumor RT plans with an anterior-posterior-posterior-anterior field setup were selected as references. For each reference, a 2D digitally reconstructed radiograph was computed from the reference CT to simulate a 2D radiographic image and dose reconstruction was performed on the other CTs in the respective group. Deviations in organ mean dose (DEmean) of the reconstructions versus the references were calculated, as were deviations in patient characteristics (i.e. age, height, weight) and in anatomical features including organ volume, location (in 3D), and spatial overlaps. Per reference, the Pearson's correlation coefficient between deviations in DEmean and patient characteristics/features were studied. Deviation in organ locations and DEmean for the liver, spleen, and right kidney were moderately correlated (R2 > 0.5) for 8/8, 5/8, and 3/4 reference plans, respectively. Deviations in organ volume or spatial overlap and DEmean for the right and left kidney were weakly correlated (0.3 < R2 < 0.5) in 4/4 and 1/4 reference plans. No correlations (R2 < 0.3) were found between deviations in age or height and DEmean. Therefore, the performance of organ dose reconstruction using surrogate patients' CT scans is primarily related to deviation in organ location, followed by volume and spatial overlap. Further, results were plan dependent.

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/60542947
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/60542947

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1088/1361-6498/ab1796

Supporting
Mentioning
Contrasting
2
10
0

Article citations

Similar Articles 


To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.


Funding 


Funders who supported this work.

Stichting Kinderen Kankervrij (1)