Background

Implantable cardioverter-defibrillator (ICD) therapy is the most effective prophylactic strategy against sudden cardiac death (SCD) in patients with ischemic cardiomyopathy (ICM) and left ventricle ejection fraction (LVEF) ≤35% as detected by transthoracic echocardiograpgy (TTE). This approach has been recently questioned because of the low rate of ICD interventions in patients who received implantation and the not-negligible percentage of patients who experienced SCD despite not fulfilling criteria for implantation.

Objectives

The DERIVATE-ICM registry (CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy; NCT03352648) is an international, multicenter, and multivendor study to assess the net reclassification improvement (NRI) for the indication of ICD implantation by the use of cardiac magnetic resonance (CMR) as compared to TTE in patients with ICM.

Methods

A total of 861 patients with ICM (mean age 65 ± 11 years, 86% male) with chronic heart failure and TTE-LVEF <50% participated. Major adverse arrhythmic cardiac events (MAACE) were the primary endpoints.

Results

During a median follow-up of 1,054 days, MAACE occurred in 88 (10.2%). Left ventricular end-diastolic volume index (HR: 1.007 [95% CI: 1.000-1.011]; P = 0.05), CMR-LVEF (HR: 0.972 [95% CI: 0.945-0.999]; P = 0.045) and late gadolinium enhancement (LGE) mass (HR: 1.010 [95% CI: 1.002-1.018]; P = 0.015) were independent predictors of MAACE. A multiparametric CMR weighted predictive derived score identifies subjects at high risk for MAACE compared with TTE-LVEF cutoff of 35% with a NRI of 31.7% (P = 0.007).

Conclusions

The DERIVATE-ICM registry is a large multicenter registry showing the additional value of CMR to stratify the risk for MAACE in a large cohort of patients with ICM compared with standard of care.

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/156222889
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/156222889

Article citations


Go to all (8) article citations

Similar Articles 


To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.