Europe PMC

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


Unrecognised oesophageal intubation causes preventable serious harm to patients undergoing tracheal intubation. When capnography is unavailable or doubted, clinicians still use clinical findings to confirm tracheal intubation, or exclude oesophageal intubation, and false reassurance from clinical examination is a recurring theme in fatal cases of unrecognised oesophageal intubation. We conducted a systematic review and meta-analysis of the diagnostic accuracy of five clinical examination tests and the oesophageal detector device when used to confirm tracheal intubation. We searched four databases for studies reporting index clinical tests against a reference standard, from inception to 28 February 2023. We included 49 studies involving 10,654 participants. Methodological quality was overall moderate to high. We looked at misting (three studies, 115 participants); lung auscultation (three studies, 217 participants); combined lung and epigastric auscultation (four studies, 506 participants); the oesophageal detector device (25 studies, 3024 participants); 'hang-up' (two non-human studies); and chest rise (one non-human study). The reference standards used were capnography (22 studies); direct vision (10 studies); and bronchoscopy (three studies). When used to confirm tracheal intubation, misting has a false positive rate (95%CI) of 0.69 (0.43-0.87); lung auscultation 0.14 (0.08-0.23); five-point auscultation 0.18 (0.08-0.36); and the oesophageal detector device 0.05 (0.02-0.09). Tests to exclude events that invariably lead to severe damage or death must have a negligible false positive rate. Misting or auscultation have too high a false positive rate to reliably exclude oesophageal intubation and there is insufficient evidence to support the use of 'hang-up' or chest rise. The oesophageal detector device may be considered where other more reliable means are not available, though waveform capnography remains the reference standard for confirmation of tracheal intubation.

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/150144560
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/150144560

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1111/anae.16059

Supporting
Mentioning
Contrasting
0
4
0

Article citations


Go to all (6) article citations