Abstract
Purpose
Chest tomosynthesis (CTS) has a relatively longer acquisition time compared with chest X-ray, which may increase the risk of motion artifacts in the reconstructed images. Motion artifacts induced by breathing motion adversely impact the image quality. This study aims to reduce these artifacts by excluding projection images identified with breathing motion prior to the reconstruction of section images and to assess if motion compensation improves overall image quality.Approach
In this study, 2969 CTS examinations were analyzed to identify examinations where breathing motion has occurred using a method based on localizing the diaphragm border in each of the projection images. A trajectory over diaphragm positions was estimated from a second-order polynomial curve fit, and projection images where the diaphragm border deviated from the trajectory were removed before reconstruction. The image quality between motion-compensated and uncompensated examinations was evaluated using the image quality criteria for anatomical structures and image artifacts in a visual grading characteristic (VGC) study. The resulting rating data were statistically analyzed using the software VGC analyzer.Results
A total of 58 examinations were included in this study with breathing motion occurring either at the beginning or end ( n=17 ) or throughout the entire acquisition ( n=41 ). In general, no significant difference in image quality or presence of motion artifacts was shown between the motion-compensated and uncompensated examinations. However, motion compensation significantly improved the image quality and reduced the motion artifacts in cases where motion occurred at the beginning or end. In examinations where motion occurred throughout the acquisition, motion compensation led to a significant increase in ripple artifacts and noise.Conclusions
Compensation for respiratory motion in CTS by excluding projection images may improve the image quality if the motion occurs mainly at the beginning or end of the examination. However, the disadvantages of excluding projections may outweigh the benefits of motion compensation.References
Articles referenced by this article (26)
VGC ANALYZER: A SOFTWARE FOR STATISTICAL ANALYSIS OF FULLY CROSSED MULTIPLE-READER MULTIPLE-CASE VISUAL GRADING CHARACTERISTICS STUDIES.
Radiat Prot Dosimetry, (1-4):46-53 2016
MED: 26769908
Image quality dependency on system configuration and tube voltage in chest tomosynthesis—a visual grading study using an anthropomorphic chest phantom.
Med Phys, (3):1200-1212 2015
MED: 25735275
Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection.
Acta Radiol, (6):634-639 2013
MED: 23528563
Sin-quadratic model for chest tomosynthesis respiratory signal analysis and its application in four dimensional chest tomosynthesis reconstruction.
Med Eng Phys, 59-68 2018
MED: 29336877
The Swedish CArdioPulmonary BioImage Study: objectives and design.
J Intern Med, (6):645-659 2015
MED: 26096600
Chest tomosynthesis: technical principles and clinical update.
Eur J Radiol, (2):244-251 2009
MED: 19616909
Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography.
Radiology, (1):269-277 2010
MED: 20851944
Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases.
Radiology, (3):1034-1041 2008
MED: 18849504
Show 10 more references (10 of 26)
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Image-based iterative compensation of motion artifacts in computed tomography.
Med Phys, 36(11):5323-5330, 01 Nov 2009
Cited by: 1 article | PMID: 19994540
Data-driven respiratory motion compensation for four-dimensional cone-beam computed tomography (4D-CBCT) using groupwise deformable registration.
Med Phys, 45(10):4471-4482, 18 Sep 2018
Cited by: 14 articles | PMID: 30118177 | PMCID: PMC6203328
Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model.
Med Phys, 37(6):2901-2909, 01 Jun 2010
Cited by: 59 articles | PMID: 20632601 | PMCID: PMC2887907
Reduction of ringing artifacts induced by diaphragm drifting in free-breathing dynamic pulmonary MRI using 3D koosh-ball acquisition.
Magn Reson Med, 92(5):2021-2036, 05 Jul 2024
Cited by: 0 articles | PMID: 38968132