Abstract
Full text links
Read article at publisher's site: https://doi.org/10.1111/j.1469-7793.1997.463bh.x
Read article for free, from open access legal sources, via Unpaywall: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1159877
References
Articles referenced by this article (14)
Interstitial-lymphatic mechanisms in the control of extracellular fluid volume.
Physiol Rev, (1):1-78 1993
MED: 8419962
Skeletal muscle oxygenation monitoring by near infrared spectroscopy.
Biochem Int, (2):241-248 1991
MED: 1789791
Filling and emptying of the low-pressure blood vessels of the human forearm.
J Appl Physiol, (2):573-582 1966
MED: 5934465
Deep venous contribution to hydrostatic blood volume change in the human leg.
Am J Cardiol, (7):449-453 1988
MED: 3414521
Changes in subcutaneous interstitial fluid pressure, tissue oxygenation, and skin red cell flux during venous congestion plethysmography in men.
Microcirculation, (1):75-81 1997
MED: 9110285
A reassessment of mercury in silastic strain gauge plethysmography for microvascular permeability assessment in man.
J Physiol, 407-422 1993
MED: 8229810
The effect of passive tilting on microvascular parameters in the human calf: a strain gauge plethysmography study.
J Physiol, 541-552 1997
MED: 9032701
VASCULAR ADJUSTMENTS TO INCREASED TRANSMURAL PRESSURE IN CAT AND MAN WITH SPECIAL REFERENCE TO SHIFTS IN CAPILLARY FLUID TRANSFER.
Acta Physiol Scand, 34-48 1964
MED: 14168045
Title not supplied
1987
Plasma colloid osmotic pressure in venous blood from the human foot in orthostasis.
Acta Physiol Scand, (4):447-454 1981
MED: 7348029
Show 4 more references (10 of 14)
Citations & impact
Impact metrics
Citations of article over time
Article citations
Transfusion increased skin blood flow when initially low in volume-resuscitated patients without acute bleeding.
Front Med (Lausanne), 10:1218462, 04 Oct 2023
Cited by: 0 articles | PMID: 37859856 | PMCID: PMC10582983
Validation of the mean systemic filling pressure assessment with preserved arterial blood flow by comparing two methods of calculation.
Sci Rep, 11(1):15844, 04 Aug 2021
Cited by: 0 articles | PMID: 34349219 | PMCID: PMC8338930
A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home.
Med Devices (Auckl), 14:141-154, 13 May 2021
Cited by: 3 articles | PMID: 34012302 | PMCID: PMC8128499
Impact of tetraplegia vs. paraplegia on venoarteriolar, myogenic and maximal cutaneous vasodilation responses of the microvasculature: Implications for cardiovascular disease.
J Spinal Cord Med, 45(1):49-57, 04 Jun 2020
Cited by: 1 article | PMID: 32496962 | PMCID: PMC8890560
Physiological Concentrations of Zinc Have Dual Effects on P2X Myenteric Receptors of Guinea Pig.
Cell Mol Neurobiol, 38(7):1439-1449, 14 Aug 2018
Cited by: 0 articles | PMID: 30109516
Go to all (55) article citations
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
The effect of passive tilting on microvascular parameters in the human calf: a strain gauge plethysmography study.
J Physiol, 498 ( Pt 2):541-552, 01 Jan 1997
Cited by: 31 articles | PMID: 9032701
Microvascular fluid filtration capacity (Kf) assessed with cumulative small venous pressure steps and with various degrees of tilt.
Eur J Med Res, 4(7):264-270, 01 Jul 1999
Cited by: 5 articles | PMID: 10425263
Human calf precapillary resistance decreases in response to small cumulative increases in venous congestion pressure.
J Physiol, 507 ( Pt 2):611-617, 01 Mar 1998
Cited by: 26 articles | PMID: 9518718
Clinical pharmacology, physiology and pathophysiology of superficial veins--1.
Br J Clin Pharmacol, 38(3):181-196, 01 Sep 1994
Cited by: 48 articles | PMID: 7826819 | PMCID: PMC1364788
Review Free full text in Europe PMC