Abstract
References
Articles referenced by this article (21)
A unified approach to statistical tomography using coordinate descent optimization.
IEEE Trans Image Process, (3):480-492 1996
MED: 18285133
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.
IEEE Trans Med Imaging, (5):687-699 1996
MED: 18215950
Parallelization of the EM algorithm for 3-D PET image reconstruction.
IEEE Trans Med Imaging, (4):513-522 1991
MED: 18222856
Title not supplied
Exact and approximate rebinning algorithms for 3-D PET data.
IEEE Trans Med Imaging, (2):145-158 1997
MED: 9101324
Penalized weighted least-squares image reconstruction for positron emission tomography.
IEEE Trans Med Imaging, (2):290-300 1994
MED: 18218505
Accelerated image reconstruction using ordered subsets of projection data.
IEEE Trans Med Imaging, (4):601-609 1994
MED: 18218538
Title not supplied
Title not supplied
Show 10 more references (10 of 21)
Citations & impact
Impact metrics
Article citations
Radiosynthesis and Preclinical Evaluation of m-[18F]FET and [18F]FET-OMe as Novel [18F]FET Analogs for Brain Tumor Imaging.
Mol Pharm, 21(6):2795-2812, 15 May 2024
Cited by: 0 articles | PMID: 38747353 | PMCID: PMC11151201
Deep learning-based PET image denoising and reconstruction: a review.
Radiol Phys Technol, 17(1):24-46, 06 Feb 2024
Cited by: 6 articles | PMID: 38319563 | PMCID: PMC10902118
Review Free full text in Europe PMC
Exercise Modifies the Brain Metabolic Response to Chronic Cocaine Exposure Inhibiting the Stria Terminalis.
Brain Sci, 13(12):1705, 11 Dec 2023
Cited by: 1 article | PMID: 38137153 | PMCID: PMC10742065
Longitudinal imaging of murine atherosclerosis with 2-deoxy-2-[18F]fluoro-D-glucose and [18F]-sodium fluoride in genetically modified Apolipoprotein E knock-out and wild type mice.
Sci Rep, 13(1):22983, 27 Dec 2023
Cited by: 0 articles | PMID: 38151517 | PMCID: PMC10752895
TgF344-AD Rat Model of Alzheimer's Disease: Spatial Disorientation and Asymmetry in Hemispheric Neurodegeneration.
J Alzheimers Dis Rep, 7(1):1085-1094, 26 Sep 2023
Cited by: 0 articles | PMID: 37849636 | PMCID: PMC10578321
Go to all (279) article citations
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Resolution and noise properties of MAP reconstruction for fully 3-D PET.
IEEE Trans Med Imaging, 19(5):493-506, 01 May 2000
Cited by: 141 articles | PMID: 11021692
MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.
Phys Med Biol, 48(11):1519-1537, 01 Jun 2003
Cited by: 107 articles | PMID: 12817935
[Investigation of the resolution and count recovery coefficients of a whole-body PET scanner (Shimadzu SET-2400W) in 2D and 3D mode image].
Kaku Igaku, 37(1):35-41, 01 Jan 2000
Cited by: 0 articles | PMID: 10714066
Positron emission tomography: a review of basic principles, scanner design and performance, and current systems.
Semin Nucl Med, 34(2):87-111, 01 Apr 2004
Cited by: 31 articles | PMID: 15031810
Review
Funding
Funders who supported this work.
NCI NIH HHS (2)
Grant ID: R01 CA579794
Grant ID: R01 CA69370