Europe PMC

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


More than 60% of cancer patients injected with intact murine monoclonal antibody (MAb) develop a humoral response against the antigen even after a single dose. Analysis of a series of 35 ovarian-cancer patients entered in phase-I and -II clinical studies of T-cells retargeted with the bi-specific F(ab')2 OC/TR revealed: (i) a detectable human anti-mouse antibody (HAMA) response in 31/35 (88%) patients, with high HAMA levels (> or = 150 ng/ml) in 18/31 (58%) cases by the end of the treatment; (ii) no correlation between HAMA levels and the form of delivery of the mAb (OC/TR bound to T cells or bound plus soluble), time schedule or cumulative dose; (iii) an association between high HAMA levels and favorable clinical parameters and response to immunotherapy; and (iv) a significantly longer median survival probability in patients with high HAMA levels than in patients with lower HAMA levels, even when the sub-group of non-responder patients was considered. Evaluation of the anti-idiotypic response in HAMA-positive sera indicated that 11/17 sera showed high-titer (>6000) binding of OC/TR, as evaluated by a specific radioimmunoassay, and 15/18 and 16/16 sera specifically inhibited the binding of the MOv18 and anti-CD3 parental MAbs to ovarian-carcinoma cells and T lymphocytes respectively. Of 7 patients evaluated for duration of the HAMA response, 5 showed stable or even increased HAMA levels. The long-lasting HAMA response maintained an anti-idiotypic component, directed mainly against the alphaCD3 idiotype of bi-MAb OC/TR in 2 out of 3 cases tested.

References 


Articles referenced by this article (31)


Show 10 more references (10 of 31)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1002/(sici)1097-0215(19990219)84:1<62::aid-ijc12>3.0.co;2-t

Supporting
Mentioning
Contrasting
2
6
0

Article citations


Go to all (25) article citations