Logo of jbeLink to Publisher's site
PMC full text:

Fig. 3

An external file that holds a picture, illustration, etc.
Object name is bio-1-011005-g003.jpg

Unconfined compression stress relaxation. (Top) Quarter-symmetry model used for the simulation with the free fluid flow through the outer boundaries indicated with arrows. (Bottom) Axial stress versus time calculated from the analytical solution and predicted by FEBio, showing the excellent agreement between the two results.

Images in this article

  • Fig. 1
  • Fig. 2
  • Fig. 3
  • Fig. 4
  • Fig. 5
  • Fig. 6
  • Fig. 7
  • Fig. 8
  • Fig. 9
  • Fig. 10
Click on the image to see a larger version.