Telomere length measurement by a novel monochrome multiplex quantitative PCR method

Nucleic Acids Res. 2009 Feb;37(3):e21. doi: 10.1093/nar/gkn1027. Epub 2009 Jan 7.

Abstract

The current quantitative polymerase chain reaction (QPCR) assay of telomere length measures telomere (T) signals in experimental DNA samples in one set of reaction wells, and single copy gene (S) signals in separate wells, in comparison to a reference DNA, to yield relative T/S ratios that are proportional to average telomere length. Multiplexing this assay is desirable, because variation in the amount of DNA pipetted would no longer contribute to variation in T/S, since T and S would be collected within each reaction, from the same input DNA. Multiplexing also increases throughput and lowers costs, since half as many reactions are needed. Here, we present the first multiplexed QPCR method for telomere length measurement. Remarkably, a single fluorescent DNA-intercalating dye is sufficient in this system, because T signals can be collected in early cycles, before S signals rise above baseline, and S signals can be collected at a temperature that fully melts the telomere product, sending its signal to baseline. The correlation of T/S ratios with Terminal Restriction Fragment (TRF) lengths measured by Southern blot was stronger with this monochrome multiplex QPCR method (R(2) = 0.844) than with our original singleplex method (R(2) = 0.677). Multiplex T/S results from independent runs on different days were highly reproducible (R(2) = 0.91).

Publication types

  • Research Support, N.I.H., Extramural
  • Validation Study

MeSH terms

  • Albumins / genetics
  • DNA Primers
  • Gene Dosage
  • Humans
  • Polymerase Chain Reaction / methods*
  • Polymerase Chain Reaction / standards
  • Reference Standards
  • Reproducibility of Results
  • Tandem Repeat Sequences
  • Telomere / chemistry*
  • Temperature
  • beta-Globins / genetics

Substances

  • Albumins
  • DNA Primers
  • beta-Globins