Background: T2 mapping is a magnetic resonance imaging technique measuring T2 relaxation time, which increases with the myocardial tissue water content. Myocardial edema is a component of acute cellular rejection (ACR) after heart transplantation. This pilot study compares in heart transplantation recipients a novel high resolution 3-dimensional (3D) T2-mapping technique with standard 2-dimensional (2D) T2-mapping for ACR detection.
Methods: Consecutive asymptomatic patients (n = 26) underwent both 3D T2 mapping and reference 2D T2 mapping magnetic resonance imaging on the day of endomyocardial biopsy (EMB). 3D T2 maps were obtained at an isotropic spatial resolution of 1.72 mm (voxel volume 5.1 mm3). 2D and 3D maps were matched anatomically, and maximum segmental T2 values were compared blinded to EMB results. In addition, all 3D T2 maps were rendered as 3D images and inspected for foci of T2 elevation.
Results: T2 values of segments from 2D and reformatted 3D T2 maps agreed (p > 0.5). The highest 2D segmental T2 values were 49.9 ± 4.0 ms (no ACR = 0R, n = 18), 48.9 ± 0.8 ms (mild ACR = 1R, n = 3), and 65.0 ms (moderate ACR = 2R). Rendered 3D T2 maps of cases with 1R showed foci with significantly elevated T2 signal (T2 = 58.2 ± 3.6 ms); 5 cases (28%) in the 0R group showed foci with increased T2 values (>2 SD above adjacent tissue) that were not visible on the 2D T2 maps.
Conclusions: This pilot study in a small cohort suggests equivalency of standard segmental analysis between 3D and 2D T2-mapping. 3D T2 mapping provides a spatial resolution that permits detection of foci with elevated T2 in patients with mild ACR.