Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

Property Value
dbo:abstract
  • توزيع الهواء تحت الأرضية (يو إف إيه دي) هو إستراتيجية لتوفير التهوية وتكييف المساحات في الأبنية وهو جزء من تصميم نظام التدفئة والتهوية وتكييف الهواء (إتش فّاك). تتغذى أنظمة (يو إف أيه دي) من خزان تمدد يتوضع بين إسمنت البناء ونظام أرضية مرتفعة لتوفير الهواء المكيَّف عبر موزعات أرضية مباشرةً إلى المساحة المأهولة من المبنى. أنظمة توزيع الهواء تحت الأرضية (يو إف إيه دي) تُشابه الأنظمة التقليدية العُلوية (وتسمى فوق الرأسية وتكتب اختصارًا «أو إتش») من ناحية أنواع المعدات المستخدمة في وحدات التدفئة والتبريد ووحدة مناولة (أو معالجة) الهواء المركزية (إيه إتش يو). تتضمن الاختلافات الرئيسة عن الأنظمة التقليدية استخدام خزان تمدد تحت أرضي للتغذية واستخدام هواء تغذية ذي درجة حرارة أعلى (أدفأ) وتوزيع هواء محلي لكل غرفة (مع أو بدون تحكم فردي) ووجود تراكب حراري طبقي. التراكب الحراري الطبقي أحد خصائص أنظمة توزيع الهواء تحت الأرضية (يو إف إيه دي)، التي تسمح بدرجات ضبط أعلى لحساس الحرارة (ألترموستات) بالمقارنة مع نظيرتها العُلوية (أو إتش). حساب الحمل التبريدي لأنظمة توزيع الهواء تحت الأرضية (يو إف إيه دي) يختلف عنه في الأنظمة التقليدية العُلوية (أو إتش)؛ بسبب تأثير الأرضية المرفوعة، وبالتحديد، قد يكون الحمل التبريدي عند الذروة أعلى في أنظمة توزيع الهواء تحت الأرضية من نظيرتها فوق الرأسية (أو إتش). هذا بسبب اكتساب الحرارة من فتحات الأبنية نفسها وثغراتها. لدى أنظمة توزيع الهواء تحت الأرضية عدة مزايا محتملة عن الأنظمة العُلوية التقليدية، من بينها المرونة في التركيب باختلاف التصميم الداخلي، وتحسين كل من الارتياح الحراري وأداء التهوية وتقليل استخدام الطاقة في الجو المناسب وتقليل الكلفة الإجمالية (كلفة دورة حياة النظام). تستخدم أنظمة توزيع الهواء تحت الأرضية غالبًا في أبنية المكاتب، وبشكل خاص في تصاميم المكاتب ذات المرونة العالية في إعادة التوزيع ومكاتب الطابق المفتوح حيث تكون الأرضيات المرفوعة مرغوبة لسهولة توصيل الأسلاك. تناسب أنظمة توزيع الهواء تحت الأرضية العديد من أنواع الأبنية المتنوعة بما فيها الأبنية التجارية والمدارس والكنائس والمطارات والمتاحف والمكتبات… إلخ. تضم أشهر المباني التي تستخدم أنظمة توزيع الهواء تحت الأرضية -في أمريكا الشمالية- في قائمتها مبنى النيويورك تايمز وبرج مصرف أمريكا ومبنى سان فرانسيسكو الفدرالي. تجب العناية بالتدابير والإجراءات المتخذة في مرحلة بناء أنظمة توزيع الهواء تحت الأرضية؛ لضمان إحكام خزان التمدد لاجتناب تسرب الهواء في خزانات تمدد أنظمة توزيع الهواء تحت الأرضية المستخدمة للتغذية. (ar)
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. The UFAD system takes advantage of the thermal plume and stratification phenomenon: the conditioned air is supplied directly to the occupied zone (OZ). The thermal plumes generated by the occupants and other heat sources introduce the conditioned air to absorb the heat and humidity and then bring the contaminated air to the upper zone (UZ). At a certain plane in the room, the airflow rate returned to the UZ is equal to the supply air. The plane divides the room into OZ and UZ and leads to thermal stratification: the hot and contaminated air is concentrated in the UZ, and the air in the OZ is cool and fresh. UFAD can bring several potential advantages over traditional overhead systems, including reduced life-cycle building costs; improved thermal comfort, occupant satisfaction, and productivity; improved ventilation efficiency, indoor air quality, and health; reduced energy use and static pressures; and reduced floor-to-floor height in new construction. The UFAD system was originally introduced in the 1950s for rooms with high heat loads and raised floors systems for cable and equipment management (e.g. computer rooms, control centers, etc.). The system was introduced into office buildings in the 1970s in West Germany, with the addition of occupant-controlled localized supply diffusers. Nowadays UFAD system has achieved considerable acceptance in Europe, South Africa, and Japan. UFAD is often used in office buildings, particularly highly-reconfigurable and open plan offices where raised floors are desirable for cable management. UFAD is appropriate for a number of different building types including commercials, schools, churches, airports, museums, libraries, etc. Notable buildings using the UFAD system in North America include The New York Times Building, Bank of America Tower and San Francisco Federal Building. Careful considerations need to be made in the construction phase of UFAD systems to ensure a well-sealed plenum to avoid air leakage in UFAD supply plenums. (en)
dbo:thumbnail
dbo:wikiPageExternalLink
dbo:wikiPageID
  • 29486330 (xsd:integer)
dbo:wikiPageLength
  • 28869 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1124560492 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dct:subject
gold:hypernym
rdf:type
rdfs:comment
  • توزيع الهواء تحت الأرضية (يو إف إيه دي) هو إستراتيجية لتوفير التهوية وتكييف المساحات في الأبنية وهو جزء من تصميم نظام التدفئة والتهوية وتكييف الهواء (إتش فّاك). تتغذى أنظمة (يو إف أيه دي) من خزان تمدد يتوضع بين إسمنت البناء ونظام أرضية مرتفعة لتوفير الهواء المكيَّف عبر موزعات أرضية مباشرةً إلى المساحة المأهولة من المبنى. أنظمة توزيع الهواء تحت الأرضية (يو إف إيه دي) تُشابه الأنظمة التقليدية العُلوية (وتسمى فوق الرأسية وتكتب اختصارًا «أو إتش») من ناحية أنواع المعدات المستخدمة في وحدات التدفئة والتبريد ووحدة مناولة (أو معالجة) الهواء المركزية (إيه إتش يو). تتضمن الاختلافات الرئيسة عن الأنظمة التقليدية استخدام خزان تمدد تحت أرضي للتغذية واستخدام هواء تغذية ذي درجة حرارة أعلى (أدفأ) وتوزيع هواء محلي لكل غرفة (مع أو بدون تحكم فردي) ووجود تراكب حراري طبقي. التراكب الحراري الطبقي أحد خصائص أنظمة (ar)
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. (en)
rdfs:label
  • توزيع هواء تحت الأرضية (ar)
  • Underfloor air distribution (en)
  • 地板式送风空调系统 (zh)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageDisambiguates of
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License