Practical Considerations in Oscillation Based Test of SC Biquad Filters

Authors

  • U. Kač Jozef Stefan Institute Jamova 39 1000 Ljubljana Slovenia
  • F. Novak Jozef Stefan Institute Jamova 39 1000 Ljubljana Slovenia

DOI:

https://doi.org/10.5755/j01.itc.43.1.3893

Keywords:

mixed-signal test, oscillation based test, switched-capacitor filters, test structures

Abstract

Transformation of different types of switched-capacitor (SC) biquad filter stages based on Fleischer-Laker biquad SC structure in order to support oscillation based testing (OBT) have been proposed. The derived solutions are based on the generic Fleischer-Laker biquad SC structure assuming ideal characteristics of the employed components. In this paper, we explore the operation of the proposed OBT structures in the case of non ideal components. Furthermore, the efficiency of the proposed OBT schemes in terms of achieved fault coverage in comparison with other test methods is discussed.

DOI: http://dx.doi.org/10.5755/j01.itc.43.1.3893

Downloads

Published

2014-03-07

Issue

Section

Regular Papers