Europe PMC

This website requires cookies, and the limited processing of your personal data in order to function. By using the site you are agreeing to this as outlined in our privacy notice and cookie policy.

Abstract 


No abstract provided.

Free full text 


Logo of japLink to Publisher's site
J Appl Physiol (1985). 2009 Sep; 107(3): 1002.
PMCID: PMC4073924
PMID: 19713436

Last Word on Point:Counterpoint: Exercise-induced intrapulmonary shunting is imaginary vs. real

to the editor: We completely agree with the letter writers (3) that it is important to apply quantitative techniques for the measurement of intrapulmonary shunt before drawing conclusions. Both MIGET and the 100% oxygen technique are quantitative and have consistently shown insignificant intrapulmonary shunting in most normal subjects (2, 6). Quantification of these shunts with 99mTcMAA, recently attempted (4), is problematic. This is because the 99mTcMAA technique relies heavily on assumptions about uniformity of particle size, adherence of the 99mTc to the particle, and assumptions about attenuation of counts in the face of changing respiratory muscle blood flow and pulmonary blood volume postexercise. All of these issues will bias the measurements in the direction of overestimating shunt. Additionally, 99mTcMAA has been validated only for large shunts (i.e., orders of magnitude greater than discussed here) and only against the 100% oxygen technique, which our colleagues have argued recently is invalid for detection of their arteriovenous pathways (4).

Our colleagues claim that because MIGET cannot distinguish right-to-left cardiac shunts (such as a patent foramen ovale) from intrapulmonary shunts that this somehow invalidates MIGET. All that this means is that gas exchange techniques cannot identify the physical site of a shunt, not that they cannot quantify it when present. Thus the values in Table 1 (2) are a “worst case scenario” for intrapulmonary shunt, as they may also contain contributions from any intracardiac shunt.

Precapillary gas exchange is suggested as a reason why MIGET consistently measures shunt as a miniscule contribution to the AaDO2. If a vessel exchanges gas, it is by definition, NOT a shunt vessel, although diffusion-perfusion disequilibrium is possible. The effect of a shunt is to retain gases of all solubilities (not just SF6), including those that have solubilities bracketing the respiratory gases. Furthermore, O2 also exchanges upstream of capillaries (1), so this does not explain why these techniques measure a tiny shunt and associated effect on the AaDO2.

For intrapulmonary shunts to be anything but trivially important for gas exchange one has to believe that established quantitative techniques for measurement of intrapulmonary shunting are invalid: the 100% oxygen technique because of some previously undiscovered vasoconstrictive effect of oxygen on selected parts of the pulmonary circulation (4), and MIGET because of some mysterious gas exchange properties of these “shunt” vessels acting on some of the inert gases, but not respiratory gases or inert gases with similar solubilities. Finally, if many normal individuals “shunt” during exercise, as our colleagues assert, and “shunts” are potentially important determinants of cerebrovascular pathology (3), it is surprising that that athletes the world over are not experiencing cryptogenic stroke, as they exercise daily for several hours. This would appear not to be the case.

Until our colleagues can QUANTIFY flow through dilated channels using appropriately validated techniques and until those channels can be shown to have ABNORMAL O2 uptake, they have nothing more than an hypothesis. Until both standards have been met, microbubble transmission should not be called a shunt and a role in gas exchange should not be inferred.

REFERENCES

1. Conhaim RL, Staub NC. Reflection spectrophotometric measurement of O2 uptake in pulmonary arterioles of cats. J Appl Physiol 48: 848–856, 1980 [Abstract] [Google Scholar]
2. Hopkins SR, Olfert IM, Wagner PD. Point: Exercise-induced intrapulmonary shunting is imaginary. J Appl Physiol; 10.1152/japplphysiol.91489.2008 [Europe PMC free article] [Abstract] [CrossRef]
3. Jones RL, Sheel AW, Naeije R, Faoro V, Hughes JM, Bates ML. Comments on Point:Counterpoint: Exercise-induced itrapulmonary shunting is imaginary vs. real. J Appl Physiol; 10.1152/japplphysiol.00660.2009 [CrossRef]
4. Lovering AT, Haverkamp HC, Romer LM, Hokanson JS, Eldridge MW. Transpulmonary passage of 99mTc macroaggregated albumin in healthy humans at rest and during maximal exercise. J Appl Physiol 106: 1986–1992, 2009 [Europe PMC free article] [Abstract] [Google Scholar]
5. Lovering AT, Stickland MK, Amann M, Murphy JC, O'Brien MJ, Hokanson JS, Eldridge MW. Hyperoxia prevents exercise-induced intrapulmonary arteriovenous shunt in healthy humans. J Physiol 586: 4559–4565, 2008 [Abstract] [Google Scholar]
6. Vogiatzis I, Zakynthinos S, Boushel R, Athanasopoulos D, Guenette JA, Wagner H, Roussos C, Wagner PD. The contribution of intrapulmonary shunts to the alveolar-to-arterial oxygen difference during exercise is very small. J Physiol 586: 2381–2391, 2008 [Abstract] [Google Scholar]

Articles from Journal of Applied Physiology are provided here courtesy of American Physiological Society

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.1152/japplphysiol.00652.2009

Supporting
Mentioning
Contrasting
1
14
0

Article citations


Go to all (10) article citations

Funding 


Funders who supported this work.

NHLBI NIH HHS (2)