Abstract
Free full text
Exponential Megapriming PCR (EMP) Cloning—Seamless DNA Insertion into Any Target Plasmid without Sequence Constraints
Associated Data
Abstract
We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.
Introduction
One of the most common tasks in molecular cloning is the insertion of a defined DNA fragment into a target plasmid. Traditionally this is achieved by restriction enzyme mediated sticky end [1]–[4] or blunt end [5]–[6] ligation, greatly facilitated by the advent of PCR [7]–[9]. Nonetheless the efficiency of blunt end ligation is low and sticky end cloning is limited by the availability of suitable restriction sites. To overcome these disadvantages restriction-free cloning techniques have been developed, albeit all with their own limitations. TA-cloning [10] needs special vector treatment and does not discriminate against reverse insertion of the insert. The high-throughput methods Gateway [11]–[12] and Creator cloning [13] use site-specific recombination, thus depend on specific sequence elements and, in addition, require specific vectors and expensive enzymes. In contrast, homologous recombination techniques rely on fusion of complementary sequences and thus do not need specific sequence elements. In vivo homologous recombination (reviewed in [14]) can be achieved by three mechanisms, all limited in one way or another. RecA-dependent recombination [15] requires recA+ strains and long overhangs, RecA-independent recombination [16] is of low efficiency and Red/ET dependent recombination [17] depends on strains overexpressing RedE/RedT/Redγ. Homologous recombination in vitro does not require special bacteria strains. Instead recombination is facilitated by in vitro generation of single strand overhangs. For this purpose ligation-independent cloning (LIC) [18] uses the 3′–5′ exonuclease activity of T4 DNA polymerase. Overhangs are typically generated from ~12 nt terminal sequences lacking one of the four nucleotides. The sequence restriction is necessary to avoid uncontrolled DNA digestion. In the case of sequence and ligation-independent cloning (SLIC) [19] overhangs are determined either by stopping the exonuclease reaction after a certain time, or by PCR. SLIC generated overhangs have no sequence restrictions other than being complementary to the target plasmid. SLIC requires linearizing the target plasmid by enzymatic cleavage or PCR, and the addition of RecA, for highest efficiency. Another recent in vitro recombination technique was presented by Gibson and coworkers [20]. Here double stranded DNA fragments of up to several hundred kilobases with overlapping sequences of 40 bp are assembled in a single reaction using 5′ exonuclease, DNA polymerase and DNA ligase. This method can be used for the assembly of genes and entire genomes. A common weakness of all recombination-based cloning techniques is that cloning success cannot be monitored before obtaining colonies, since the intermediary steps are not quantifiable. A megaprimer-based method, restriction-free (RF) cloning [21]–[23], is also sequence-independent and restriction-free, like SLIC, but in addition does not require enzymatic strand treatment and intermediary steps can be monitored and controlled. Traditionally, the megaprimer PCR method was used to introduce mutations, insertions and deletions into a linear DNA sequence [24]–[25] or to fuse DNA fragments [26]. In RF cloning the insert is amplified with primers containing overhangs matching a sequence of choice in the target plasmid. In a second PCR reaction the PCR product of the first reaction is used as a megaprimer for linear amplification of the target plasmid. The resulting product can be observed via agarose gel electrophoresis and, in case of success, be transformed. This method works reasonably well for inserts up to 5 kb in length, although in practice efficiency is reduced for inserts >2–3 kb. A major disadvantage of RF cloning is low product yield due to linear PCR amplification, which becomes prohibitive for larger inserts.
To overcome the limitations of current cloning methods, we developed exponential megapriming PCR (EMP) cloning. EMP cloning shares the advantages of RF cloning, but lifts the size limits for the inserts. EMP requires two consecutive PCR steps, which are both designed to amplify the template exponentially rather than linearly. In the first step, the insert is amplified, and in the second step the insert is integrated into the plasmid ( Fig. 1A ). Both steps can also be combined into a single PCR reaction. Importantly, simultaneous insertion of several DNA fragments is possible with EMP cloning.
Materials and Methods
Exponential Megapriming PCR (EMP) Cloning
Overview of EMP cloning
The first step of EMP cloning is the exponential amplification of the insert of choice and the addition of a 3′ overhang by PCR. The product of this 1st EMP PCR is used in a second PCR reaction as a megaprimer to exponentially amplify the target plasmid together with a short reverse primer ( Fig. 1A ). The product of this 2nd EMP PCR is then in vitro phosphorylated, ligated and transformed into competent E. coli cells. Single colonies are screened for proper plasmid generation by standard methods, i.e. analytical restriction digest, colony-PCR, or by sequencing.
Synthesis of the EMP megaprimer
For the synthesis of the megaprimer two primers are used in an exponential PCR reaction (1st EMP PCR). The forward primer (F1) typically has 20–25 nt and matches the 5′ region of the insert. The reverse primer (R1) is 40–50 nt in size and contains a 20–25 nt sequence with reverse complementarity to the region on the target plasmid immediately downstream of the insertion site, followed by the reverse complement of the 3′ end of the insert. The 1st EMP PCR reactions contains 1× HF Phusion buffer (NEB), 200 µM of each dNTP, 0.5 µM primer F1, 0.5 µM primer R1, 25 ng template DNA, and 0.02 U/µL Phusion DNA Polymerase (NEB) in a volume of 50 µl. In rare cases GC Phusion buffer and/or the addition of up to 3% (v/v) dimethylsulfoxide (DMSO) can increase the reaction efficiency. The PCR conditions are: initial denaturation step (30 s, 98°C), followed by 25 cycles of denaturation (10 s, 98°C), annealing (30 s, Tm (F1/R1) +3°C) and extension (15 s/1 kb, 72°C). A final extension cycle (5 min, 72°C) completes the PCR reaction. For the annealing temperature the lower of the calculated melting temperature of either F1 or the insert binding part of R1 is used. Tm values were calculated using OligoAnalyzer 3.1 (IDT). Product of the 1st EMP PCR is analyzed by agarose gel electrophoresis and purified with a PCR purification kit (E.Z.N.A. Cylce Pure Kit, Omega bio-tek). See also Table S1.
Insertion of the EMP megaprimer
The megaprimer is used together with a 20–25 nt primer R2, reverse complementary to the region 5′ of the insertion site on the target plasmid, to exponentially amplify the target plasmid. The amount of megaprimer is not critical and can be fairly low (25–400 ng), since the re-use of primer F1 again in the 2nd EMP PCR ensures high product yield. In the first cycles the megaprimer and R2 generate a starting population of insert fused with target plasmid. After the megaprimer is depleted, primers F1 and R2 continue to exponentially amplify the linear product. The 2nd EMP PCR contains 1× HF Phusion buffer, 200 µM of each dNTP, 0.5 µM primer F1, 0.5 µM primer R2, 25 ng–400 ng megaprimer, 25 ng template DNA, and 0.02 U/µL Phusion DNA Polymerase (NEB) in a volume of 50 µl. The amount of megaprimer should be screened. If F1 is added to the reaction 25–50 ng megaprimer are sufficient. In rare cases the addition of F1 leads to secondary PCR products and thus low product amounts. In those cases no F1 and megaprimer amounts between 100–400 ng should be tried, with the highest success rate at 200 ng in our tests. PCR optimization is performed as described for the 1st EMP PCR. The 2nd EMP PCR starts with an initial denaturation step (30 s, 98°C), followed by 25 cycles of denaturation (10 s, 98°C), annealing (30s, Tm (F1/R1/R2) +3°C) and extension (30 s/1 kb, 72°C) with no final extension. For the calculation of the annealing temperature the lower Tm of either R2, F1, or the plasmid binding sequence of the megaprimer is used. The product of the 2nd EMP PCR is analyzed by agarose gel electrophoresis and purified with a PCR purification kit. The product is eluted in 30 µl of 10 mM Tris-HCl (pH 8.0), 1 mM EDTA. See also Table S1.
In vitro ligation and transformation of EMP product
16.5 µl product of the 2nd EMP PCR is incubated in 1× T4 DNA ligase buffer (NEB) with 5 U T4 PNK for 30 min at 37°C to add a 5′ phosphate. The product is circularized by ligation with 200 U of T4 DNA ligase for 1 h at room temperature. Remaining parental plasmid is digested by adding 10 U DpnI for 30 min at 37°C. 5 µL of the 20 µL reaction are used for the transformation into 50 µL of chemically competent E. coli DH5α cells.
One-step EMP Cloning
EMP cloning allows to couple megaprimer production and insertion into the target plasmid in a single PCR reaction. In a one-step EMP PCR reaction limiting amounts of the overhang containing primer R1 are used to reach primer depletion in the first cycles. The resulting small amount of megaprimer generates a starting population of product template for the exponential amplification through forward primer F1 and reverse primer R2. A typical reaction contains 0.02 µΜ πριμερ Ρ1, 0,5 µΜ πριμερ Φ1 ανδ 0.5 µΜ πριμερ Ρ2 ιν αδδιτιον το 1× HF Phusion buffer, 200 µM of each dNTP, 25 ng template DNA for the insert, 25 ng template DNA for the target plasmid, and 0.02 U/µL Phusion DNA Polymerase (NEB) in a 50 µΛ ρεαχτιον. See also Table S2.
Multi-insert EMP Cloning
EMP cloning allows for insertion of several megaprimers at once. The first step of EMP cloning is performed independently for each megaprimer. In the 2nd PCR step 50 ng of each megaprimer are added to 1× HF Phusion buffer, 200 µM of each dNTP, 0.5 µM primer F1, 0.5 µM primer R2, 25 ng template DNA, and 0.02 U/µL Phusion DNA Polymerase (NEB) in a 50 µΛ ρεαχτιον. Megaprimer 3′ overhangs are designed such that they bind, in nested manner, the 5′ end of another insert. The terminal insert then binds to the plasmid backbone 3′ of the insertion site. In an exponential amplification reaction forward primer F1 anneals to the beginning insert ensuring that all inserts are getting amplified. Reverse primer R2 binds 5′ of the insertion site. In vitro ligation and transformation are performed as in regular EMP cloning. See also Table S3.
Restriction-free (RF) Cloning
Overview RF cloning
The protocol is modified from the original protocol published in van den Ent and Löwe [22]. In the first step of RF cloning the insert of choice gets amplified and overhangs at 3′ and 5′ end are added. The product of this 1st RF PCR is used in a 2nd PCR as a megaprimer to linearly amplify the target plasmid ( Fig. 1B ). The product of this 2nd RF PCR can either be directly transformed, or first in vitro ligated and then transformed in competent E. coli cells. Single colonies are picked, grown and control digests are performed.
Synthesis of the RF megaprimer
For the synthesis of the megaprimer two 40–50 nt primers are used in an exponential PCR reaction (1st RF PCR). The forward primer (F1) has a 20–25 nt region identical with the sequence 5′ of the insertion site of the target plamsid, followed by 20–25 nt matching the 5′ end of the insert. The reverse primer (R1) is also 40–50 nt long and contains 20–25 nt in reverse complementarity to the sequence 3′ of the insertion site of the target plasmid, followed by the reverse complement of the 3′ end of the insert. The resulting product is the exponentially amplified insert containing 5′ and 3′ overhangs and its complementary strand. Besides the two primers the 1st RF reaction has the same reaction conditions as the 1st EMP PCR. Optimization is performed as for the 1st EMP PCR. For the calculation of the annealing temperature the lower Tm of either the insert binding part of F1 or the insert binding part of R1 is used. The product of the 1st RF PCR is analyzed by agarose gel electrophoresis and purified with a PCR purification kit. See also Table S4.
Insertion of the RF megaprimer
The megaprimer is used to linearly amplify the target plasmid. The overhangs of the megaprimer bind 5′ and 3′ of the insertion site on the target plasmid. A new product strand does not contain a binding site for the reverse megaprimer and is therefore not a template for the next round of PCR, causing a linear rather than exponential amplification. The 2nd EMP PCR contains 1× HF buffer (NEB), 200 µM of each dNTP, 100 ng–400 ng megaprimer, 25 ng template DNA, and 0.02 U/µL Phusion DNA Polymerase (NEB). The amount of megaprimer has to be screened. PCR optimization is performed as for the 1st PCR reaction. The 2nd RF PCR reaction starts with an initial denaturation step (30 s, 98°C), followed by 35 cycles of denaturation (10 s, 98°C), annealing (30s, Tm (F1/R1) +3°C) and extension (30 s/1 kb, 72°C) with no final extension. The product of the 2nd RF PCR is analyzed by agarose gel electrophoresis and purified with a PCR purification kit. See also Table S4.
Ligation and transformation of the 2nd RF PCR product
Van den Ent and Löwe [22] suggest to directly add DpnI to the finished 2nd RF PCR reaction and incubate for 2 h to digest parental plasmid, followed by transformation in E. coli cells. Since the two complementary product strands can form a circular double stranded plasmid with two single strand nicks in vivo ligation can occur in E. coli cells, albeit with low efficiency.
We instead performed an in vitro ligation by incubating the purified 2nd RF PCR product in T4 ligase buffer (NEB) with 5 U PNK for 30 min at 37°C, followed by 1 h incubation at room temperature with 200 U of T4 ligase and incubation for 30 min at 37°C with 10 U DpnI. The product is then transformed in E. coli DH5α cells.
The advantage of direct DpnI incubation and transformation of the 2nd RF PCR reaction, as suggested in [22], is to save time and labor by not performing DNA purification, PNK and T4 ligase incubation. However, the in vivo ligation protocol has severe disadvantages. First, the efficiency of DpnI in PCR buffer is reduced compared to T4 ligase buffer or NEB buffer 4, resulting in higher background due to incompletely digested parental plasmid. Second, in vivo ligation of doubly nicked plasmids is inefficient.
To better compare EMP cloning to RF cloning by eliminating influences of differential product treatment after 2nd PCR we decided to perform RF cloning with in vitro ligation.
General PCR Optimization
Difficulties during DNA amplification by PCR can arise from the nucleotide sequence of primers and template. Secondary structure motifs, such as intramolecular hairpins, in the primer sequence can inhibit annealing to the template. Formation of primer homo-dimers or hetero-dimers dilute the effective primer concentration and, if primers get extended, also the effective polymerase concentration and nucleotide concentration. These problems can be minimized by a careful primer design [27]–[28]. Tools for designing primers are available online. Other reasons for PCR failure are GC-rich sequences and base pair repeats in the DNA template [29]–[30]. GC-rich sequences can lead to the formation of stable, non-B form secondary structure motifs. The ability of the polymerase to amplify difficult templates can be improved by optimizing the PCR buffer by adding Mg2+, DMSO, glycerol or formamide [29]–[30] or using commercial buffers for GC-rich sequences. A general way to trouble-shoot PCR reactions is to vary the primer annealing temperature. Initially an annealing temperature close to the lower melting temperature of the used primers should be tested. If this leads to low product amounts a lower annealing temperature should be tried to allow primer binding. If it results in bands of unwanted products a higher annealing temperature should be tried to avoid unspecific priming [31]–[32]. PCR errors by the polymerase can be reduced to a minimum by using high fidelity polyermases such as Phusion Polymerase or Pfu Turbo II instead of Taq polymerase [33]–[36] and by reducing the number of PCR cycles. PCR error rates can be calculated with web tools like the fidelity calculator by Thermo Fisher (http://www.thermoscientificbio.com/webtools/fidelity/).
Results
The Concept and Mechanism of Exponential Megapriming PCR (EMP) Cloning
The in vitro mutagenesis PCR method QuikChange [37]–[38] is the conceptual basis for RF cloning, just that it introduces single mutations or small insertions or deletions <50 bp instead of entire genes. In the QuikChange PCR reaction a complementary primer pair binds to the target site leading to linear product amplification. Although the efficiency of these short manipulations is fairly high, PCR products can often not be observed due to low product amounts. In analogy to how RF cloning relates to QuikChange, EMP cloning relates to inverse PCR (iPCR) [39] ( Fig. 2 ). iPCR can be used for the same manipulations QuikChange was developed for, but it uses non-overlapping primers for exponential target amplification, resulting in drastically higher product amounts and ultimately more positive clones. iPCR was originally problematic due to the relatively high error-rate of native, thermostable DNA polymerases, such as Taq. Since the introduction of genetically engineered polymerases with extraordinarily low error-rates, such as Phusion and PfuUltra II, there is no longer a disadvantage of PCR amplifying large pieces of DNA, such as vector backbones [33]–[36]. EMP cloning now uses the mechanism of iPCR to introduce complete genes.
In EMP cloning the insert is amplified with a forward primer (F1) without and a reverse primer with overhang (R1) ( Fig. 1A ). This leads to a product with 3′ overhang complementary to a landing sequence downstream of the desired insertion site in the plasmid. In the second PCR reaction the overhang binds to the target plasmid at the landing site and a second short primer (R2) binds upstream of the insertion site, mimicking the two primers of an iPCR reaction, and resulting in exponential product amplification. After megaprimer depletion the re-used primer F1 and primer R2 continue to exponentially amplify the linear product. This allows relatively low amounts of megaprimer (25 ng) ( Fig. 1A , Table S1 and Materials and Methods). In RF cloning in comparison, the first PCR reaction uses two overhang containing primers (F1 and R1) to amplify the insert and to create a megaprimer with two overhangs. In the second PCR this megaprimer binds 3′ and 5′ of the insertion site thus product amplification is linear. ( Fig. 1B , Table S4 and Materials and Methods).
EMP cloning follows a simple protocol leading to bacterial colonies in one day ( Fig. 3 ). The products of the 1st EMP PCR and 2nd EMP PCR can be analyzed on an agarose gel and purified with a PCR purification kit. The final product needs to be 5′ phosphorylated with T4 Polynucleotide Kinase (PNK), ligated with T4 Ligase and incubated with the restriction enzyme DpnI to digest the parental plasmid. These three enzymatic steps take about 2 h. The product is then transformed into competent E. coli cells and colonies are obtained the next day.
Comparison of EMP Cloning and RF Cloning
To test the performance of EMP cloning we compared it directly to RF cloning. We designed 10 test cases with insert lengths from 0.3 to 5 kb, resulting in plasmids of 3.9 to 13.6 kb ( Table 1 ). First we compared the product intensities of the 2nd PCR ( Fig. 4A and Fig. S1). Expectedly, EMP cloning consistently and reproducibly yielded more product than RF cloning, which can then be monitored more easily by gel electrophoresis. Higher product amounts let to more colonies ( Fig. 4B ). EMP yielded ~1500 colonies whereas RF about 5-fold less (~300 colonies). For inserts >2.5 kb the colony number dropped in both methods. Whereas EMP cloning still produced ≥ 30 colonies, for RF cloning the number of colonies dropped to an average of 8, and in three cases there were ≤ three colonies. This drastically reduces cloning efficiency in the RF setup.
Table 1
Case | Insert length (bp) | Template plasmidlength (bp) | Product plasmidlength (bp)a | EMP: numberof coloniesb | RF: numberof coloniesb | EMP: positive clonesout of 10 clonesc | RF: positive clonesout of 10 clonesc |
1 | 300 | 3741 | 3909 | 4552 | 81 | 9 | 7 |
2 | 492 | 7615 | 8104 | 2704 | 888 | 8 | 1 |
3 | 588 | 7483 | 7525 | 3280 | 1144 | 10 | 8 |
4 | 814 | 7414 | 7598 | 896 | 89 | 8 | 5 |
5 | 1740 | 7881 | 9614 | 1540 | 844 | 8 | 3 |
6 | 2517 | 3741 | 6126 | 2136 | 1 | 6 | 1 |
7 | 2778 | 5904 | 8676 | 72 | 8 | 1 | 0 |
8 | 3618 | 5904 | 9516 | 30 | 0 | 5 | 0 |
9 | 4230 | 5904 | 10128 | 47 | 3 | 5 | 0 |
10 | 4965 | 10220 | 13656 | 157 | 29 | 2 | 2 |
To compare the cloning efficiency, we isolated plasmids of 10 colonies per experiment, if available, and did a control restriction digest ( Fig. 4C and Fig. S2). Compared to RF cloning, the efficiency of EMP cloning was better in 9 cases, and equal in one case. On average the EMP cloning efficiency was more than twice as high as RF cloning. Again the advantage of EMP cloning versus RF cloning is especially pronounced for inserts > 2.5 kb. EMP cloning worked in all cases, RF cloning failed in three cases.
One-step Reaction and Insertion of Multiple Inserts
EMP cloning is suitable for coupling of megaprimer production and insertion in a single reaction and for adding several inserts into a plasmid simultaneously.
In order to further improve time efficiency of EMP cloning experiments we developed a one-step protocol for EMP. The experiment can be shortened by combining the 1st and 2nd EMP PCR in one reaction, followed by one purification. One-step EMP cloning uses limited amounts of overhang containing primer (R1). This generates a small population of megaprimers, sufficient to initiate the production of the desired product plasmid. Primer F1 and R2 then exponentially amplify the product plasmid ( Fig. 5A , Table S2 and Materials and Methods). One-step EMP cloning was tested by inserting a 492 bp fragment into a vector using three different amounts of R1 primer. The PCR reaction worked in all cases ( Fig. 5B ) and correct clones were obtained (Fig. S3).
EMP is an ideal tool for efficient and precise plasmid assembly. To make EMP an even more suitable tool for demanding cloning procedures we developed a multi-insert EMP protocol, enabling simultaneous insertion of several consecutive DNA fragments into a vector ( Fig. 6A ). This is useful for the generation of plasmids for co-expression of proteins. Multi-insert EMP assembles independently produced megaprimers in a single reaction. Megaprimer 3′ overhangs are designed such that they bind in nested manner. The terminal insert then binds to the plasmid backbone downstream of the insertion site. Again Primer F1 and R2 are used to exponentially amplify the product plasmid, where primer F1 binds to the 5′ end of the first insert ensuring that all inserts are getting amplified. The reverse primer R2 binds upstream of the insertion site. (Materials and Methods and Table S3). In our test case, we used an empty plasmid and successfully added three ORFs (339 bp, 549 bp, 1155 bp), in one PCR reaction ( Fig. 6A and 6B ).
Discussion
EMP is a fast, cost efficient method for seamless insertion of DNA fragments (up to 5 kb inserts tested) into any target plasmid (up to 10.2 kb tested). Using this technology, one can replace or add ORFs, tags or other DNA elements in a one-day procedure leaving no scars behind. Importantly, the method is suitable for most insert lengths of practical importance, when protein expression is concerned. In addition EMP cloning also allows the insertion of multiple sequences at once.
As shown in our comparison study EMP cloning is qualitatively and quantitatively superior to RF cloning by generating higher PCR product amounts, higher colony numbers and a higher ratio of positive clones over background. The improvement is most prominent for inserts > 2.5 kb, where EMP cloning is still very reliable while RF cloning is not.
An important feature of EMP cloning is the option to perform both PCRs in one reaction, which is mechanistically not possible with RF cloning. This speeds up the experimental procedure. The downside of one-step EMP is the missing control checkpoint after the 1st EMP PCR, therefore a potential failure cannot be traced easily. Although one-step EMP is an attractive option, the standard two-step protocol is probably more reliable since less aberrant amplifications are possible.
The strongest advantage of EMP over contemporary recombination based cloning techniques like SLIC is the possibility to monitor the success of vector-insert fusion prior to transformation: a potential failure can be corrected at an earlier stage, saving time. Furthermore the intensity of the product band provides an estimate of the resulting clone efficiency and thus of the number of clones necessary for successful screening.
The high flexibility in choice of insert and vector, seamless insertion and the high efficiency of EMP cloning make this method an ideal tool for any application that requires the generation of plasmid libraries, for example expression libraries for structural biology. Last but not least, EMP cloning is automatable and should be easily applicable to high-throughput efforts.
Supporting Information
Figure S1
Agarose gels of 2nd EMP and 2nd RF PCRs of the 10 test cases. Products of 2nd EMP and 2nd RF PCRs are shown on agarose gels. Product lengths are indicated in parenthesis. The 2nd PCRs of case 3 are shown twice since RF only worked on the second attempt.
(TIF)
Figure S2
Control digests of the 10 test cases. Agarose gels of control digests of the 10 test cases are shown. If 10 or more colonies were obtained in an experiment, 10 plasmids were isolated and digested with appropriate restriction enzymes. If less then 10 colonies were obtained, all colonies were analyzed. Circles around colony numbers indicate clones with the expected band patterns. Sizes of the expected products from restriction analysis are indicated to the left of the gels.
(TIF)
Figure S3
Colony PCR of one-step EMP reaction. Agarose gel of colony PCRs of 7 clones obtained by one-step EMP. 4 out of 7 clones show the right PCR product at 948 bp.
(TIF)
Table S4
Restriction-free cloning PCR protocol.
(TIF)
Acknowledgments
We thank S. Bilokapic for critical reading of the manuscript and we thank members of the Schwartz lab for testing the EMP method and providing feedback while it was in development.
Funding Statement
This work was supported by National Institutes of Health Grant GM077537 to TUS. AU acknowledges a predoctoral fellowship from the German Academic Exchange Service (DAAD). KRA was funded by the Lundbeck Foundation and a Sapere Aude DFF postdoc grant. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
References
Articles from PLOS ONE are provided here courtesy of PLOS
Full text links
Read article at publisher's site: https://doi.org/10.1371/journal.pone.0053360
Read article for free, from open access legal sources, via Unpaywall: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0053360&type=printable
Citations & impact
Impact metrics
Citations of article over time
Alternative metrics
Smart citations by scite.ai
Explore citation contexts and check if this article has been
supported or disputed.
https://scite.ai/reports/10.1371/journal.pone.0053360
Article citations
In vivo cloning of PCR product via site-specific recombination in Escherichia coli.
Appl Microbiol Biotechnol, 108(1):400, 29 Jun 2024
Cited by: 0 articles | PMID: 38951186 | PMCID: PMC11217044
A Major Facilitator Superfamily Transporter Contributes to Ergot Alkaloid Accumulation but Not Secretion in Aspergillus leporis.
Appl Microbiol (Basel), 4(1):406-417, 20 Feb 2024
Cited by: 0 articles | PMID: 39055383 | PMCID: PMC11271707
Accelerated Long-Fragment Circular PCR for Genetic Manipulation of Plant Viruses in Unveiling Functional Genomics.
Viruses, 15(12):2332, 28 Nov 2023
Cited by: 2 articles | PMID: 38140572 | PMCID: PMC10747169
Overlap extension cloning of PCR products into a Gateway-compatible plasmid vector.
Biotechniques, 75(1):363-370, 09 Jul 2023
Cited by: 0 articles | PMID: 37424091 | PMCID: PMC10388215
Molecular basis for recognition and deubiquitination of 40S ribosomes by Otu2.
Nat Commun, 14(1):2730, 12 May 2023
Cited by: 5 articles | PMID: 37169754 | PMCID: PMC10175282
Go to all (49) article citations
Data
Data behind the article
This data has been text mined from the article, or deposited into data resources.
BioStudies: supplemental material and supporting data
Similar Articles
To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.
Mega primer-mediated molecular cloning strategy for chimaeragenesis and long DNA fragment insertion.
Biosci Rep, 37(2):BSR20160608, 02 Mar 2017
Cited by: 3 articles | PMID: 28183872 | PMCID: PMC5333777
A restriction-free method for gene reconstitution using two single-primer PCRs in parallel to generate compatible cohesive ends.
BMC Biotechnol, 17(1):32, 17 Mar 2017
Cited by: 6 articles | PMID: 28302113 | PMCID: PMC5356277
Polishing the craft of genetic diversity creation in directed evolution.
Biotechnol Adv, 31(8):1707-1721, 06 Sep 2013
Cited by: 48 articles | PMID: 24012599
Review
Inverse fusion PCR cloning.
PLoS One, 7(4):e35407, 17 Apr 2012
Cited by: 18 articles | PMID: 22530019 | PMCID: PMC3328455
Funding
Funders who supported this work.
NIGMS NIH HHS (2)
Grant ID: R01 GM077537
Grant ID: GM077537