Abstract 


The Sensititre Autoreader system is an instrument-assisted broth microdilution susceptibility test procedure based on the detection of fluorogenic growth substrate metabolism by test bacteria with different concentrations of antimicrobial agents. In the current investigation, this system was assessed as a means for predicting the in vitro activity of 17 antimicrobial agents versus numerous species of the family Enterobacteriaceae and Pseudomonas aeruginosa by using a breakpoint broth microdilution test format. Same-day and overnight determinations of susceptibility were made with the Sensititre Autoreader system, and in both cases, the results were compared with those obtained with a manual overnight breakpoint broth microdilution susceptibility test. Among a total of 6,086 organism-antimicrobial agent comparisons with Enterobacteriaceae, concordance was noted between the results of the same-day Autoreader system and the manual overnight test in 94.4% of cases. The same-day Autoreader results with members of the Enterobacteriaceae other than Proteus spp. were determined after 4 h of incubation; with Proteus spp. the same-day Autoreader results were determined after 5 h of incubation. When the Enterobacteriaceae Autoreader results were determined after 18 h of incubation, concordance was noted in 97.2% of comparisons. Among a total of 1,377 organism-antimicrobial agent comparisons with P. aeruginosa after 18 h of incubation, agreement of results from the manual overnight test and the Autoreader system was achieved in 92.2% of cases.

Free full text 


Logo of jcmLink to Publisher's site
J Clin Microbiol. 1987 Aug; 25(8): 1481–1485.
PMCID: PMC269253
PMID: 3114321

Sensititre autoreader for same-day breakpoint broth microdilution susceptibility testing of members of the family Enterobacteriaceae.

Abstract

The Sensititre Autoreader system is an instrument-assisted broth microdilution susceptibility test procedure based on the detection of fluorogenic growth substrate metabolism by test bacteria with different concentrations of antimicrobial agents. In the current investigation, this system was assessed as a means for predicting the in vitro activity of 17 antimicrobial agents versus numerous species of the family Enterobacteriaceae and Pseudomonas aeruginosa by using a breakpoint broth microdilution test format. Same-day and overnight determinations of susceptibility were made with the Sensititre Autoreader system, and in both cases, the results were compared with those obtained with a manual overnight breakpoint broth microdilution susceptibility test. Among a total of 6,086 organism-antimicrobial agent comparisons with Enterobacteriaceae, concordance was noted between the results of the same-day Autoreader system and the manual overnight test in 94.4% of cases. The same-day Autoreader results with members of the Enterobacteriaceae other than Proteus spp. were determined after 4 h of incubation; with Proteus spp. the same-day Autoreader results were determined after 5 h of incubation. When the Enterobacteriaceae Autoreader results were determined after 18 h of incubation, concordance was noted in 97.2% of comparisons. Among a total of 1,377 organism-antimicrobial agent comparisons with P. aeruginosa after 18 h of incubation, agreement of results from the manual overnight test and the Autoreader system was achieved in 92.2% of cases.

Full text

Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (994K), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References.

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Doern GV, Dascal A, Keville M. Susceptibility testing with the sensititer breakpoint broth microdilution system. Diagn Microbiol Infect Dis. 1985 May;3(3):185–191. [Abstract] [Google Scholar]
  • Staneck JL, Allen SD, Harris EE, Tilton RC. Automated reading of MIC microdilution trays containing fluorogenic enzyme substrates with the Sensititre Autoreader. J Clin Microbiol. 1985 Aug;22(2):187–191. [Europe PMC free article] [Abstract] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Alternative metrics

Altmetric item for https://www.altmetric.com/details/79912835
Altmetric
Discover the attention surrounding your research
https://www.altmetric.com/details/79912835

Article citations